[sebhc] H8/H17 emulator available to prelim. trials
Walter Moore
waltm22 at comcast.net
Mon May 24 18:01:05 CDT 2004
The "SPACE" feature used underruns and framing errors to determine what the
next baud rate to try was. I don't know how you would emulate this. Bit 6
of I/O port 362Q (from the XCON card) allowed the baud rate to be set to
9600 by default. Emulating the XCON card might be easier if you haven't.
..walt
> -----Original Message-----
> From: sebhc at sebhc.org [mailto:sebhc at sebhc.org] On Behalf Of Dave Dunfield
> Sent: Monday, May 24, 2004 3:32 PM
> To: sebhc at sebhc.org
> Subject: Re: [sebhc] H8/H17 emulator available to prelim. trials
>
>
> >Hi Dave
> > It seems like they did an auto baud but I'm not sure.
> >Dwight
>
> Hi Dwight,
>
> that occuired to me - I do recall reading somewhere that an configured
> disk auto-bauds, however this "should" with my emulated serial port (it
> will of course lock onto the first baudrate that it tries).
>
> IIRC, it was supposed to autobaud on a SPACE character - I tried typing
> LOTS of spaces --- no dice.. Hopefully Steven or someone else imtimately
> familier with the Heath systems will be able to tell me exactly what it's
> doing ...
>
> Regards,
> Dave
> --
> dave04a (at) Dave Dunfield
> dunfield (dot) Firmware development services & tools: www.dunfield.com
> com Vintage computing equipment collector.
> http://www.parse.com/~ddunfield/museum/index.html
>
> --
> Delivered by the SEBHC Mailing List
--
Delivered by the SEBHC Mailing List
More information about the Sebhc
mailing list