Hi Dwight,
One of my H8's is configured with an H8-5 and an H-17
controller. It works just fine ...
The default port configuration for the H8-5 has the serial
port at 372Q/373Q, and the cassette port at 370Q/371Q.
The H-17 default (as I recall) is at 174Q-177Q ...there is
no conflict to my knowledge (I haven't pulled out the docs
to verify)...
Scott
----- Original Message -----
From: "Dwight K. Elvey" <dwight.elvey at amd.com>
To: <sebhc at sebhc.org>
Sent: Thursday, May 27, 2004 7:43 PM
Subject: [sebhc] H8 configuration
> Hi
> I'm going to be setting up my older H8 to have the
> H17 board installed. The problem is that this machine
> has only the serial/cassette board ( H8-5 ) and not
> the H8-4 serial board. Is this configuration possible?
> I know that on the H89, the cassette and H17 are on
> conficting addresses. Can one configure this older
> setup to run without using the H8-4 board? Is there
> a way to share or disable the cassette address on the
> H8-5 board?